Vacuum Sizing: Holding Force F=PA, Leak Rate and Ejector Flow Calculation
The Vacuum Cup That Dropped the Carton Every Other Cycle We picked up cardboard cartons with a single Ø50 mm vacuum cup. The holding force was calculated at about 12 N (at -60 kPa). The carton weighed 0.5 kg (5 N). The math said it would hold. On the floor, it dropped every other cycle. …
Continue reading “Vacuum Sizing: Holding Force F=PA, Leak Rate and Ejector Flow Calculation”